Four New Product Groups Available

Instrumentation cables and thermocouple extension cables for applications in the oil and gas sector as well as the chemical, pharmaceutical, and food and beverage industries.

Instrumentation Cables

HELUKABEL, one of the leading global manufacturers and suppliers of cable, wires, and accessories, recently announced the launch of four new in-stock instrumentation and compensating cable product groups for applications in the oil and gas sector, as well as for use in the chemical, pharmaceutical, and food and beverage industries.

Reliable data transmission is a must, even under the most extreme conditions. As a result, HELUKABEL developed new robust instrumentation cables (HELUDATA®) and compensating cables (HELUTHERM®) for sophisticated applications to ensure the continuous transmission of sensitive measurement data even under harsh conditions. These new cable products come in various designs and insulation materials and guarantee minimum losses, even over long distances. Configuration options include conductors that are wrapped in a single or double shield, as well as cables with an overall shield, and with or without wire armour. This ensures that the right cable version can be found for each application. Both cable series feature a robust PVC jacket and are certified according to European, US (UL), and Canadian (cUL) standards along with their halogen-free, flame-retardant (LS0H) variants. The LS0H versions can be used in areas where corrosive or toxic combustible gases are not permitted. HELUTHERM® compensating cables for thermocouple connection are available in a diverse variety of metal combinations. All cables are resistant to UV rays, sunlight, and oil.

control room with raffinery in the background
Everything in view: here in the control room all central data converge - all the more important that the cables and wires used transmit the signals reliably and error-free even over long distances.

These cables are used wherever processes need to be controlled and monitored: they transmit measurement data on temperature, pressure or flow rate, for example, and are used to control valves, temperature regulators and pilot lamps. Especially in onshore plants such as refineries or chemical plants, the distances between the control room and the component to be controlled (such as a valve, control lamp or sensor) can be very long.

Product overviews are listed below:

HELUDATA® PLTC UL13HELUTHERM® PLTC UL 13 / ANSI MC 96.1
  • The "UL counterpart" to HELUDATA® EN-50288-7
  • Power Limited Tray Cable (PLTC) for unprotected installation in cable trays
  • Two material combinations (conductor/jacket):
    PVC/PVC (105°C) & XLPE/LS0H
  • Pairs and triads:
    18 - 14 AWG
  • Thermocouple extension cables according to ANSI MC 96.1 with approval for PLTC UL 13
  • For temperature measurement
  • Power Limited Tray Cable (PLTC) for unprotected installation in cable trays
  • Two material combinations (conductor/jacket):
    PVC/PVC (105°C) & XLPE/LS0H
  • Types: KX; JX; EX; TX
HELUDATA® EN-50288-7HELUDATA® EN-50288-7 FIRE RES
  • Instrumentation cables according to EN 50288-7
  • Pairs, triads and quads:
    20 - 14 AWG (0.5 - 2.5 mm²)
  • Four constructions:
    with and without armouring, elements individually and overall shielded, overall shield only
  • Three material combinations (conductor/jacket):
    PVC/PVC & XLPE/PVC & XLPE/LS0H
  • Instrumentation cables with improved fire behavior for functional integrity
  • Fire resistant according to IEC 60331-21
  • Four constructions:
    with and without armouring, elements individually and overall shielded, overall shield only
  • Halogen-free

Learn more about our instrumentation cables:

Data sheets are available for download here: www.helukabel.de/new-instrumentation-datasheets

Furthermore we offer additional products for process automation:

PROFIBUS PA

FOUNDATION™ Fieldbus

Single Pair Ethernet (SPE) 1x2xAWG18 10BASE-T1L

Cable Glands

As a system provider, we also supply the appropriate accessories, such as:

HELUTOP® HT-MS-EX-d

HELUTOP® HT-MS-EX-d 1 EMC

HELUTOP® HT-MS-EX-d/e4

DOWNLOADS

Press Release: PDF

Back